1. Infrared carbon sulfur analyzer is designed by our company, and applies highly integrated circuit board, electronic components are preferably in automotive grade, this will extend service life and reduce fault rate.
2. This model high frequency carbon sulfur analyzer uses 24-bit Analog-to-Digital Converter chip and 4-channel acquisition (high carbon, low carbon, high sulfur, low sulfur). 4-channel Analog-to-Digital (AD) signal acquisition, passes through four signal analysis pools in turn during analysis, then generates 4 AD signals and automatically read 4 sets of available signals.
Product Introduction

In the testing of steel, casting and alloy materials, the carbon and sulfur content often requires batch testing. For laboratories that need to process more samples every day, too long a single analysis time will directly affect testing efficiency and production release pace.
The carbon and sulfur analyzer uses high-frequency furnace heating and infrared absorption method. The carbon and sulfur analysis time is 20–40 seconds, and the sensitivity can reach 0.00001% (0.1 ppm) under specific conditions.; The carbon measurement range covers 0.00001%–10%, and the sulfur measurement range covers 0.00001%–5%. The range can be extended by adjusting sample weight. For laboratories that need to continuously conduct material composition testing, single sample analysis time can be shortened while taking into account detection sensitivity.
Carbon and Sulfur Analyzer Parameters
| Parameters | Specification |
| Test Range | C: 0.00001%-10% (Measuring range can be extended by changing sample weight.) S: 0.00001%-5% (Measuring range can be extended by changing sample weight.) |
| Weight of Sample | 0.01g-1g The sample weight can be adjusted according to sample content. |
| Test Error | C: Comply with ISO 9556, S: comply with ISO 4935 |
| Sensitivity | C/S: 0.00001% (0.1ppm) |
| Accuracy | C: 1 ppm or 0.5%RSD, S: 1 ppm or 1.0%RSD |
| Analysis Time | 20s to 40s |
| Power Supply of Host Machine | AC 200/220/240 V ±10%, 50/60 Hz ±1 Hz, 5 kVA. |
| Carrier Gas | High-purity oxygen, purity ≥99.9% (or ≥99.99% depending on configuration), pressure 0.3–0.5 MPa. |
| Power Gas | Nitrogen or purified compressed air, pressure 0.3–0.5 MPa. |
| Package Size and Weight | 580mm*680mm*840mm, 130kg, Fumigation-free wooden box. |
| Minimum Order Quantity | 1 unit |
| Payment Terms | 100% TT in advance |
| Mode of Transportation | Shipping by sea |
Carbon and Sulfur Analyzer Features
1. The analytical gas path of this carbon sulfur analytical instrument adopts precise electronic mass flow meter control technology, this will accurately control gas flow.
2. High-frequency combustion of the carbon and sulfur analyzer applies full functional power control technology, this will effectively prevent sample splashing, reduce damage to spare parts, and extend the service life of spare parts.
3. Analysis software uses vertical touch screen, users can choose single vertical screen display (vertical screen display is on host machine) and double vertical screen display (one is on host machine, the other is the computer display), this will makes users conveniently and rapidly set analysis method, analysis control, on-line diagnosis and data report.
4. In the high frequency carbon sulfur analyzer, local area network communication is applied, realizing data synchronization and export.
5. Chinese and English operation interfaces can be switched with one key.
6. Automatic vacuum cleaning system is included in the high frequency infrared carbon sulfur analyzer.
7. The high frequency infrared carbon sulfur analyzer applies 32-bit single-chip microcomputer, it will improve computation speed and accuracy.
8. Constant temperature infrared detection cell of this model carbon sulfur analytical instrument applies constant temperature insulation technology, which will eliminated interference from external environmental temperature. In pulse modulated infrared electronic light source system, it cancels chopper motor and chopper blade, decreasing mechanical damage and frequency error.
Carbon and Sulfur Analyzer Standard Configuration
Standard Configuration
Host Machine
Operation Software
Dust Collection Device
Computer
Electronic Balance
Optional Configuration
Regulated Power Supply
Printer
Typical Application Scenarios:
1. Steel material composition testing
It is used for testing the carbon and sulfur content in steel, cast steel and related metal materials. It can be used for raw material inspection, production process inspection and finished product quality control. For laboratories that need to continuously test multiple samples, an analysis time of 20 - 40 seconds can improve daily testing efficiency.
2. Casting and alloy material testing
During the casting process, the carbon and sulfur content will directly affect the control of material composition. X1CS can be used for carbon and sulfur analysis of cast iron, cast steel and alloy materials, helping the laboratory confirm the composition of different batches of materials.
3. Inspection of ore, coke and non-metallic solid materials
The application scope of X1CS is not limited to metal materials, but can also be used for carbon and sulfur testing in solid materials such as ore, coke, cement, ceramics, and oxides. It is suitable for material laboratories, scientific research institutions and related quality testing scenarios.
About Peny

PENY focuses on the development, production and sales of elemental analyzers. The company's predecessor, Shanghai Pengni Optoelectronics Technology Co., Ltd., was established in 2014, and its production base will be moved to Nantong Information Valley Industrial Park, Jiangsu Province in 2023. It currently has more than 2000 square meters of production space and 12 years of experience in element analyzer design and production.
Our company has a professional R & D and production team. The R & D personnel have more than 10 years of industry experience. Currently, it can provide more than 15 kinds of element analyzer products, covering the analysis of elements such as carbon, sulfur, oxygen, nitrogen and hydrogen.
In terms of production capacity, the factory currently produces about 20 - 30 analyzers per month. For standard orders, regular delivery times are approximately 30 days after order confirmation; special configurations usually require an additional approximately 5 - 7 days. Each equipment is inspected and calibrated before leaving the factory to confirm the status of the equipment before arranging delivery.

At present, the company has obtained:
· ISO 9001 Quality Management System Certification
· Trademark Registering Certificate
· Relevant qualifications of * high-tech enterprises

Carbon Sulfur Analyzer Warranty

PENY selects products based on customers 'testing materials, testing elements, testing scope and laboratory use needs. For customers with clear testing needs, they can confirm the sample type and testing requirements before purchasing, and then determine the equipment configuration to reduce the situation of re-adjusting equipment after purchasing.
It also provides one-year warranty service after the equipment is put into use. During the warranty period, if equipment malfunctions are caused by production process or material quality problems, PENY is responsible for free maintenance; if the malfunctions are caused by human operation or force majeure, cost-price maintenance services are provided.
Customer Case

Wafangdian Bear Group
Wafangdian Bearing Group was founded in 1938 and produces over 20000 specifications of bearing products with various precision levels. With the rapid development, Wafangdian Bearing Group needs to meet the needs of the domestic high-end equipment manufacturing industry. They found us and visited our factory, after testing for many times, they finally purchased our carbon sulfur analyzer.

Institute of Metal Research, Chinese Academy of Sciences
Institute of Metal Research, Chinese Academy of Sciences requires high-precision carbon sulfur and oxygen nitrogen hydrogen analysis techniques to support their research work in multiple new material research fields. After communicating and field investigation, they purchased 1 unit carbon sulfur analyzer and 1 unit OHN analyzer from our company. When we send the instruments to their institute and after installing and adjusting, they highly appreciated these 2 analyzers.
FAQ
Q: Do you have a factory?
A: Yes, we have our own factory. We are manufacturer of elemental analyzer for 12 years, we have our own factory and research team. We appreciate your visit.
Q: Do you sell spare parts and consumbles of elemental analyzers?
A: Yes, we sell spare parts and consumbles of elemental analyzers with high quality and reasonable price. If you have any need, pls feel free to contact us.
Q: What materials is your analyzer packaging with?
A: Our elemental analyzer will be packaged with packing list, factory inspection report, user's mannual before leaving factory. If you need any other certificate, pls let us know freely.
Q: What is the usual transportation method for PENY X1CS?
A: We use fumigation-free wooden boxes for packaging when exporting to reduce the impact of collision, extrusion and humid environment on the equipment during transportation. The specific methods such as sea transportation can be determined based on the order destination and customer requirements.
Q: What is the minimum order quantity for PENY X1CS?
A: The first purchase, laboratory equipment update, or project testing can start with a single equipment, and there is no need to reach a large purchase quantity.