2. The pulse furnace adopts circulating water cooling, and the sample can be heated to a high temperature of 3500 ℃ in the graphite crucible of the high-power pulse furnace to ensure full combustion and improve testing accuracy.
Product Introduction

A slightly higher oxygen level in metals, alloys, powders, or advanced materials can cause porosity, cracks, poor weldability, reduced fatigue life, and unstable electrical or thermal performance. Too often, it is found only after the batch has failed downstream processing or customer inspection — when the cost is already scrap, rework, delayed delivery, and damaged customer confidence.
Waiting 3–7 days for third-party testing delays incoming material approval and stalls production. Without fast, reliable oxygen determination, teams rely on supplier certificates, delayed testing, or guesswork — risking both accepted bad material and rejected good material.
Our Solution
The PENY X2O Oxygen Elemental Analyzer delivers fast, stable, and traceable oxygen results on solid samples from ppm to percentage levels. Based on inert gas fusion, it supports methods such as ASTM E1019 for steel, iron, nickel, and cobalt alloys, and ISO 4491 for metallic powders.
Typical analysis time: 2–3 minutes
Analysis range: 0.05 ppm – 20%
Detection limit: < 0.05 ppm
Repeatability: RSD < 1.5% (content > 50 ppm)
Sample weight: 0.03 g – 1.5 g
Key features: pulse furnace with water-cooled transformer · high-purity argon carrier gas system · imported gas-path components · automatic loading, degassing, release, calibration, integration, and blank subtraction · LIMS-compatible data export
What this means for your team: verify incoming material in 2–3 minutes instead of waiting 3–7 days · monitor process stability · release qualified batches faster · support supplier audits with traceable data · reduce dependence on external labs
Want to see how the X2O performs on your material? Send us a sample for testing.
Technical Specifications
| Parameter | Specification |
|---|---|
| Analysis range | Low: 0.05 ppm – 0.5% |
| High: 0.5% – 20.0% | |
| Analysis time | Typically 2-3 minutes, depending on sample type, weight, flux, and furnace program |
| Pulse furnace | Water-cooled transformer |
| Current | 0 – 1500 A |
| Furnace head | Automatic cleaning function |
| Power | 10 kVA |
| Maximum temperature | Up to 3500°C (nominal) |
| Heating program | Programmable heating function |
| Gas path system | Cylinders, gas path joints, air pipes, and solenoid valves use imported components |
| Carrier gas | High-purity argon gas, 99.999%, 0.3 – 0.5 MPa |
| Power gas | Ordinary nitrogen gas or purified compressed air, 0.3 – 0.5 MPa |
| Host machine power supply | AC 200/220/230/240 V ± 10%, 50/60 Hz ± 1 Hz |
| Dimensions | 850 × 700 × 655 mm (W × D × H) |
| Weight | 160 kg |
| Packaging | Fumigation-free wooden box |
Note: Actual analysis time and performance depend on sample preparation, flux selection, crucible condition, gas purity, and calibration. We recommend sample testing before final configuration.
Instrument Features
Vertical touch screen software: Single vertical screen display or dual-screen display is optional.
Automatic cleaning option: Built-in automatic cleaning system available. Software controls automatic furnace head cleaning and automatic negative-pressure dust collection.
Independently developed software: The operating software is developed by PENY. Communication protocols can be customized according to user requirements.
Data traceability: Analysis results, calibration data, and blank values are recorded for review and export.
Standard Configuration
Host machine
Operating software
Computer
Electronic balance
Dust collection device
Optional Configuration
Regulated power supply
Water cooler
Additional options such as custom communication protocols, spare parts kits, and extended service packages are available on request.
Installation Requirements
To ensure stable performance, please prepare the following before installation:
Power supply: AC 200/220/230/240 V ± 10%, 50/60 Hz ± 1 Hz
Carrier gas: High-purity argon, 99.999%, 0.3 – 0.5 MPa
Power gas: Ordinary nitrogen or purified compressed air, 0.3 – 0.5 MPa
Environment: Clean, ventilated, low-dust room with stable temperature and humidity
Cooling: Water cooler may be required depending on configuration and usage intensity
Space: Allow enough space for the host machine, computer, gas cylinders, and maintenance access
Workbench: Must support the weight of the host machine and accessories
Our team will provide a detailed pre-installation checklist after order confirmation.
Typical Applications
| Application | Typical Samples | Why It Matters |
|---|---|---|
| Steel, iron, and alloys | Steel, iron, nickel, cobalt alloys | Oxygen affects cleanliness, inclusions, mechanical properties, and weldability |
| Metallic powders and powder metallurgy | Iron powder, copper powder, alloy powder, sintered parts | Oxygen affects sintering, flowability, density, and porosity |
| Bearing, automotive, aerospace, and welding | Bearing steel, critical components, filler metals, welding wire | Oxygen deviation can reduce fatigue life, cause weld defects, and increase failure risk |
Note: Best suited for solid inorganic samples. Not for organic materials, liquids, or volatile samples. Sample testing recommended before configuration.
About Peny
PENY is a professional elemental analyzer manufacturer in China with 12 years of experience. Our factory is located in Nantong City, Jiangsu Province, with more than 2,000 m² of production space. Our research team consists of experienced technical personnel who have worked in this industry for over 10 years. We currently offer more than 15 types of analyzers for different customer requirements.
Our factory can produce 20–30 units per month. Standard analyzer delivery is approximately 30 days after order confirmation. For special configurations, please allow an additional 5–7 days. Each instrument is checked and calibrated before shipment.
We have obtained ISO 9001 certification and registered our trademark. We are also applying for high-tech enterprise recognition.


ISO 9001 certificate

Quality Control
Every PENY X2O Oxygen Elemental Analyzer is produced under a documented quality control system.
Incoming inspection — Key components such as the pulse furnace, gas path components, solenoid valves, and electronic modules are inspected against incoming quality standards before production.
Assembly control — Gas path, furnace head, and electrical wiring are checked at each stage to prevent leakage, signal drift, and connection faults.
Calibration and factory testing — Each unit is calibrated and tested with standard samples before shipment. Performance is verified per ASTM E1019 for steel, iron, nickel, and cobalt alloys, and ISO 4491 for metallic powders, covering detection limit, repeatability, and analysis range. Units that fail factory acceptance are not released for shipment.
Traceability — Each instrument has a production and inspection record. Calibration data and test results are archived for quality traceability.
Packaging — Fumigation-free wooden box with protective measures for the host machine, accessories, and gas path components.
PENY has obtained ISO 9001 certification. Inspection and calibration records are available for review.
Customer Case

ZhenTe New Material Technology Co.,Ltd.
ZhenTe New Material Technology is a manufacturer of research and development of new material and metal products. They have very strict requirement for the test. After meeting in our factory, they purchased carbon sulfur analyzer and ONH analyzer. The production efficiency is greatly improved.

Wafangdian Bear Group
Wafangdian Bearing Group was founded in 1938 and produces over 20000 specifications of bearing products with various precision levels. With the rapid development, Wafangdian Bearing Group needs to meet the needs of the domestic high-end equipment manufacturing industry. They found us and visited our factory, after testing for many times, they finally purchased our carbon sulfur analyzer.
Warranty
| Item | Terms |
|---|---|
| Warranty period | 12 months from installation or 15 months from shipment, whichever comes first |
FAQ
Q: Do you offer free training?
A: Yes. We offer free customer training after installation. Training can be provided by video, phone, or on-site if necessary. Travel and accommodation costs for on-site training may be discussed separately.
Q: How often should CO2 absorbent and color-changing desiccant be replaced?
A: There is no fixed replacement cycle. It depends on usage frequency and sample type. If discoloration or performance drift is observed, replace them promptly.
Q: What is the delivery period?
A: Standard delivery is approximately 30 days after order confirmation. Special configurations may require an additional 5–7 days. We will confirm the exact delivery date before order placement.
Q: Can you test our samples before we buy?
A: Yes. We recommend sample testing before configuration. Please contact our sales team for the sample submission procedure and testing lead time.
Q: What information should we provide for a quotation?
A: Please provide your sample type, expected oxygen range, sample size, testing frequency, voltage requirement, and any special software or communication needs.
Q: What is the minimum order quantity?
A: 1 unit.
Q: How is the analyzer shipped?
A: Shipping by sea. Packaging is fumigation-free wooden box.